Home / Service areas / Bethesda / TPO roofing
TPO roofing in Bethesda, MD: the wind record, the code lines and the roof edge
A TPO membrane is only as secure as its edge, and wind is the weather number the Maryland code text ties to that edge. This page counts the wind rows NOAA logged under the Bethesda label, sets them beside the county design table and the code text for low-slope roofs, then follows the edge test the code names for roof-edge metal, ANSI/SPRI ES-1. Where a document is silent, the page says so.
- 11 wind rows under the Bethesda label
- 115 mph on the county design sheet
- 3 ES-1 edge tests: RE-1, RE-2, RE-3
Eleven wind rows, nine dates
NOAA records wind in knots, and the type on every Bethesda row is EG, an estimated gust. The miles per hour below are our conversion at 1.15 mph per knot.
- July 18 and 19, 2016Four rows: three logged between 3:14 and 3:15 in the afternoon on the 18th, one on the 19th. Each is 50 knots, about 58 mph.
- April 21, 2017One row at 50 knots.
- May 2 and August 20, 2019One row each, both at 50 knots.
- April 30, 2021One row at 50 knots.
- May 22 and July 12, 2022One row each, both at 50 knots.
- July 29, 2023One row at 65 knots, about 75 mph, the highest under the label.
Five of the eleven years have no wind row under the label: 2015, 2018, 2020, 2024 and 2025. The county file is wider and shows the season.
| Months | County wind rows | Share |
|---|---|---|
| December to March | 52 | 11.1% |
| April and May | 96 | 20.5% |
| June to August | 286 | 61.0% |
| September to November | 35 | 7.5% |
469 Montgomery County thunderstorm wind rows on 131 dates, NOAA files for 2015 to 2025 downloaded October 19, 2026 and recounted October 20. January has no rows. Shares are rounded and are ours.
Of the 469 county rows, 209 sit at exactly 50 knots, 60 fall between 60 and 65 knots and 9 are above 65. The rows per year run from 5 in 2018 to 75 in 2019, and the file does not say why. NOAA defines the location field as the town from which the range is calculated, so it is a reference point, not the edge of Bethesda.
The wind lines in the county and code documents
Three documents put numbers or tests on a flat roof in Bethesda. They do not measure the same thing, so they are set side by side and not compared.
TPO in the material table
The single-ply table lists thermoplastic polyolefin under ASTM D6878, beside PVC under D4434, KEE under D6754 and EPDM under D4637. Single-ply roofs need a design slope of at least one quarter in 12 for drainage. The wind testing language in 1504.4.1 is written for single-ply as a family, so the text gives no wind label for TPO by name. It asks for the assembly to be tested.
County design sheet
Dated August 13, 2026. Wind speed 115 mph, ground snow load 30 psf. A ground load is not a roof load, and the sheet gives neither a risk category nor a value by address.
Code text, wind
Section 1504.4 has adhered or mechanically attached single-ply roofs resist component and cladding pressures. Section 1504.4.1 sends them to FM 4474, UL 580 or UL 1897 testing.
Code text, weathering
Section 1504.7 asks low-slope coverings to survive 2,000 hours of accelerated weathering. Where wind flexes the membrane, there must be no significant loss of tensile or breaking strength.
SPRI, the single-ply trade association, writes that Chapter 15 relies on FM 4474, UL 580 and UL 1897 for uplift and on ES-1 and GT-1 for edge securement, and that its free Directory of Roof Assemblies lists tested low-slope assemblies. The code also cites FM numbers (FM 4474 and FM 4470). FM Approvals runs a product guide and a roofing tool called RoofNav; its home page gives no roof wind ratings.
Where the roof edge test comes in
Section 1504.6 of the Maryland text covers metal edge systems on single-ply roofs under 2 in 12 slope. Gutters and counterflashing are excluded, and gutters that secure the membrane edge are tested under SPRI GT-1 instead. The edge systems must be designed for wind loads under Chapter 16 and tested under RE-1, RE-2 and RE-3 of ANSI/SPRI ES-1.
“to simulate a billowing membrane”
RE-1 test method, ANSI/SPRI/FM 4435/ES-1 2022, on why the membrane is pulled at 25 degrees- RE-1
- Pulls the membrane at an angle to the deck, in pounds per lineal foot. It is required only where the edge itself holds the membrane, which the standard calls dependent termination.
- RE-2
- Loads the vertical face of an edge flashing or fascia whose exposed horizontal part is 4 inches or less. Results come in pounds per square foot.
- RE-3
- The test for copings, with top and face loads applied together, used where the exposed horizontal part is more than 4 inches.
- Which one
- It depends on how the membrane is attached. Ballasted, spot or ribbon adhered, and mechanically attached more than 12 inches from the edge are dependent. Adhered, or fastened within 12 inches, is independent.
The commentary adds that an adhered system is assumed to put no stress on the edge unless the metal is loosened or the membrane peels under the pressure difference, and that recent hurricane investigations showed both can happen. It also says the precision and bias of the test methods have not been determined.
Corners, perimeters and what is not tested
The 59 percent figure is about built-up roofs, not TPO. SPRI adds that edge pressures at perimeter zones will be lower than its corner results.
What the documents say
- SPRI’s calculator note gives corner-zone edge pressures with a 2.0 safety factor for an enclosed building.
- The ES-1 commentary says pressure coefficients vary by building height and by perimeter or corner position.
- No special test is required for a fabricated miter, but the edge system it is made from must meet the corner-region design load.
- SPRI’s 2018 position is that each fabricator needs its own tested product.
What they leave to others
- The design pressure for a Bethesda building: SPRI’s calculator is out of service and asks for height, exposure and risk category by email.
- Which risk category and exposure apply to a given address.
- Whether county amendments change the Maryland text; they were not read for this page.
From code line to a label you can read
- Measure the slope. The edge rule applies under 2 in 12. Above that the single-ply table still applies, but the low-slope edge section does not.
- Get the design pressure from someone qualified. The county sheet gives a speed, not a pressure at a corner. An engineer or the building department turns it into one.
- Name the attachment. Ballasted, adhered or mechanically attached, and the distance of the first fasteners from the edge, decide the ES-1 route.
- Ask for the test paperwork. ES-1 says edge components or packaging carry written documentation of what was tested, available to the owner or a representative. Ask for it before the metal is ordered.
- Check the installation instructions. The standard requires instructions that include fastener and cleat requirements, so the roofer should follow the tested detail, not a similar one.
On a replacement, section 1512.4 adds that rusted, damaged or deteriorated metal edgings, drain outlets and counterflashings shall not be reinstalled. Section 1512.2.1 allows a new protective coating over existing single-ply without tear-off, and section 1512.2.1.1 bars a recover where the roof is water soaked or already has two or more coverings.
Lines to put in a Bethesda TPO quote
- The roof slope, measured on site, and the drainage it relies on.
- The attachment method and, if mechanical, the distance from the edge to the first fastener row.
- The edge detail: fascia, flashing or coping, its face height and horizontal depth.
- The ES-1 documentation for that exact edge metal, and who fabricated it.
- The assembly test route (FM 4474, UL 580 or UL 1897) and the listing relied on.
- The state of the old edge metal, counterflashings and drain outlets, and which are reused.
- Any written reply from DPS, the building owner or an association that the scope depends on.
The county’s Home Improvements page says it does not include municipality or homeowner association rules. Our Bethesda roofing guide sets out the contractor license check and the permit lanes. Book a phone consultation to talk through a Bethesda TPO roof, and see the general TPO roofing guide, roofing materials, commercial roofing, roof replacement and services pages.
Primary documents behind this page
Each source below was opened on October 20, 2026, except the NOAA files, downloaded October 19 and recounted October 20. UpCodes publishes the Maryland code text; the county amendments were not read.
- Maryland Building Code 2021, Chapter 15 Roof Assemblies and Rooftop Structures, and MBPS Residential Code 2021, Chapter 9, as published by UpCodes
- ANSI/SPRI/FM 4435/ES-1 2022, Test Standard for Edge Systems Used with Low Slope Roofing Systems
- SPRI Wind Design Calculator page, SPRI position on ES-1 tested products (May 2018) and SPRI, Five Codes, One Country (August 13, 2026)
- FM Approvals home page
- NOAA NCEI Storm Events Database, bulk detail files 2015 to 2025, with the bulk file format document
- Montgomery County DPS: Home Improvements and Residential Restore / Repair Permit Process
- Montgomery County DPS: Climatic and Geographic Design Criteria (dated August 13, 2026) and Master List of Building Codes and Standards, which names the 2021 International Building Code, effective December 10, 2024
Questions people ask
What wind number does Montgomery County list for Bethesda?
The county’s climatic and geographic design criteria sheet, dated August 13, 2026, lists a wind speed of 115 mph and a ground snow load of 30 psf. The sheet names no risk category, does not say whether 115 is an ultimate or allowable speed, and gives no value by address. DPS or a design professional confirms what applies.
Does the Maryland code text set a wind rating for a TPO membrane?
It sets a test route, not a single rating. For mechanically attached or adhered single-ply roofs the text calls for testing under FM 4474, UL 580 or UL 1897, and for ballasted single-ply roofs it points to ANSI/SPRI RP-4. TPO itself appears in the single-ply table with ASTM D6878 as its material standard.
What is ANSI/SPRI ES-1 and does it apply to a TPO roof?
ES-1 is a test standard for metal roof edge systems under simulated wind load. The code text applies it to metal edge systems on single-ply roofs under 2 in 12 slope, with gutters and counterflashing handled separately. It tests the edge metal, not the membrane, so a TPO roof meets it through its perimeter flashing, fascia or coping.
Which ES-1 test applies to my roof edge?
The standard sorts edges by how the membrane is held. Ballasted, spot or ribbon adhered systems, and mechanically attached systems fastened more than 12 inches from the edge, need RE-1 and RE-2. Fully adhered systems, or mechanical attachment within 12 inches, need RE-2 or RE-3. Where the exposed horizontal part is 4 inches or less, the face takes RE-2, and where it is wider the edge takes RE-3.
How many severe wind events has NOAA logged for Bethesda?
Under the Bethesda begin-location label for 2015 through 2025, NOAA lists 11 thunderstorm wind rows on 9 dates. Ten are 50 knots and one is 65 knots, all estimated gusts. A label is a reference town, not a boundary, and rows are not storms.
Does the code text mention hail for low-slope roofs?
Not by name in the chapter 15 text stored for this page. It does list impact tests for low-slope coverings, ASTM D3746, ASTM D4272 or the foot-traffic test in FM 4470, and an accelerated weathering test. NOAA logged one hail row, 1.75 inches on June 2, 2019, under the Bethesda label.
Does replacing a TPO roof in Bethesda need a new edge system?
The reroofing section says existing metal edgings that are rusted, damaged or deteriorated shall not be reinstalled, and it requires flashings to follow the manufacturer’s instructions. It does not say that sound edge metal must be replaced. Ask the roofer to record the edge condition in the written scope and ask DPS how it reads the job.
Who decides what edge metal goes on an association-owned flat roof?
The county pages describe building code and permit rules, not association rules, and the county says it does not enforce covenants. For a condo, co-op or rental building, the party that owns the roof under the governing documents signs the scope. Ask the board or manager before a bid is accepted, and book a phone consultation if you want to talk through a Bethesda TPO roof.
Talk through your roof with Roofers of Arlington
Share the address, what you are seeing on the roof and the decision you need to make. We will tell you what to expect before anything is scheduled.