Fiberglass shingles: what they are, what the code labels mean and what to put in writing

A fiberglass shingle is an asphalt shingle built on a glass-fiber mat. The trade associations define it, the Virginia Residential Code attaches labels and installation rules to it, and Arlington's historic records show it on the roofs of older neighborhoods. This guide is neutral: it explains the product and the paperwork around it, and where a source is silent it says so.

  • Glass-fiber mat, asphalt coating, mineral granules
  • ASTM D3462 is the product standard NRCA recommends
  • Four nails per strip shingle is the code floor

What a fiberglass shingle is made of

The National Roofing Contractors Association (NRCA) describes the product in three parts: a fiberglass mat in the middle, a layer of asphalt above and below it, and mineral granules pressed into the top. The granules are what you see from the ground. NRCA says asphalt shingles can be reinforced with organic or fiberglass materials, so "fiberglass shingle" names the reinforcement, not a separate material.

1

Mat

The glass-fiber layer holds the shape of the shingle and carries the asphalt.

2

Asphalt

Coats both faces of the mat and holds the granules on.

3

Granules

The mineral surface. NRCA notes copper-coated granules can be applied to protect against algae.

NRCA recommends shingles that comply with ASTM D3462, the specification for asphalt shingles made from glass felt and surfaced with mineral granules. It says not every shingle complies and that a compliant one is normally noted in the manufacturer's literature and on the package wrapper. That wrapper is worth keeping a photo of.

Three-tab, laminated and other forms

The Asphalt Roofing Manufacturers Association (ARMA) sorts steep-slope asphalt products into four groups. The first two are the ones most owners meet.

Strip, including three-tab

About three times as long as wide, told apart by the number of cutouts or tabs; the three-tab is the most common strip.

Laminated

More than one layer of tabs for extra thickness; also called three-dimensional or architectural.

Interlocking

Designed to fasten mechanically to one another, for greater wind resistance.

Large individual

Rectangular or hexagonal, without cutouts or tabs.

Source for the four forms: ARMA, Types of Asphalt Roofing (page dated May 2, 2017).

Two cautions from the same associations. NRCA says laminated grades give a textured look, which is a matter of appearance and not a code class. ARMA says most manufacturers do not recommend installing new shingles over existing laminated shingles, a point that matters when an owner asks about covering an old roof.

The labels the Virginia code asks for

Virginia adopted the 2021 International Residential Code as part of its building code. The roof chapter is read here on UpCodes, a third-party copy, because the code publisher's own site blocks automated reading; check the current official text with the county. Section R905.2 covers asphalt shingles, and the part that applies to a fiberglass shingle can be read as a chain of labels.

A limit the test makers state

ARMA says the standards evaluate shingles as manufactured. It also says the fire test installs shingles per the manufacturer's instructions, including underlayment, so a roof laid differently may have unknown fire resistance.

  • Product standard. R905.2.4 says asphalt shingles comply with ASTM D3462.
  • Wind label. R905.2.4.1 says shingles are tested to ASTM D7158 and the package bears a label naming that test and the class required for the site's ultimate design wind speed. Shingles outside D7158's scope may carry an ASTM D3161 label instead.
  • Limit on the wind test. A footnote to the code's wind table says the D7158 calculations assume Exposure Category B or C and a building height of 60 feet or less; other conditions need additional calculations.
  • Fire class. ARMA describes the roof-covering fire tests, ASTM E108 and UL 790, as giving Classes A, B and C, with A highest, and says they do not address fires starting inside the building.

The wind class a given site needs comes from the code's own table, which is set out on our roofing materials page; this page does not repeat it. Ask the county which design wind speed applies to your address.

Installation rules that sit around the shingle

A shingle's label means little without the parts under and around it. The same code section sets these, and they are what a written scope can name.

1

Deck and slope

Shingles go on a solidly sheathed deck, on slopes of 2:12 or more. From 2:12 up to 4:12 the code requires double underlayment.

2

Underlayment

Felt and self-adhering products named in the code (ASTM D226, D1970, D4869, D6757) must carry a compliance label. ARMA says shingles should not be laid straight on a wood deck.

3

Ice barrier

Where the code's table records a history of ice at eaves, the barrier runs at least 24 inches inside the exterior wall line. The page does not say whether Arlington is designated.

4

Nails

Corrosion-resistant roofing nails of 12-gage shank and 3/8 inch head, reaching at least 3/4 inch into the sheathing, and not fewer than four per strip shingle.

5

Valleys

Lined before shingling: an open metal valley at least 24 inches wide, or roll roofing options the code lists, or a self-adhering substitute.

6

Sidewalls

Flashing at least 4 by 4 inches, continuous or stepped, with the vertical leg continuous under siding.

ARMA's nailing bulletin adds that an improperly adjusted pneumatic tool can cause sealing failures, raised tabs and blow-offs, and that nails belong below the sealant strip. Above a 21:12 slope the code hands installation entirely to the manufacturer's instructions.

ARMA bulletins on ventilation and application

ARMA publishes residential technical bulletins that read as plain-language companions to the code. Four are useful before signing anything.

Ventilation

ARMA ties attic ventilation to shingle buckling from deck movement, rot, moisture in insulation and ice dams. It describes intake at the eaves and exhaust at the ridge, split so that intake supplies 50 to 60 percent of the open area and exhaust 40 to 50 percent. It cites a long-standing ratio of 1 square foot of net free vent area per 150 square feet of attic floor, which codes generally allow to be reduced to 1 per 300 where features such as balanced ventilation and vapor retarders are present. The bulletin also warns that mixing different exhaust vent types above one attic can short-circuit airflow.

Underlayment

The underlayment bulletin lists felt types (ASTM D226 Type I and Type II, D4869) and self-adhering membranes (D1970). It says ventilation matters more when self-adhering underlayment covers the whole deck, because that layer behaves as a vapor retarder.

Replacement versus recover

The reroofing bulletin uses the code's terms: replacement removes the old covering and repairs the substrate; a recover adds a covering over the old one. It says local codes may limit the number of layers, that tear-off lets the deck be inspected, and that a reroof should include a check of attic ventilation. It also says impact ratings may be affected by a recover.

Drip edge and steep slopes

The residential index also lists bulletins on drip edge at eaves and rakes and on shingles above 21:12. These are the places a scope most often goes quiet, so ask whether the installer's instructions for them were read.

What Arlington records say

Arlington's historic nominations are the county's own written record of what is on older roofs. They name asphalt shingles but never a product. Two examples, both re-read from the Virginia Department of Historic Resources text:

Arlington Forest (2005). The nomination counts four roof forms, with the side gable on 85 percent of houses, and says every roof is clad in asphalt shingles except two in standing seam metal, at 117 North Galveston Street and 398 North Edison Street. It adds that the original shingles came in blends of red, green, purple and blue-black.

Glebewood Village (2004). The nomination describes many side-gabled houses with slate shingles and lists, among minor alterations, replacing slate with asphalt. It says those alterations have "very little impact on the integrity of the dwelling."

Where the nominations are silent

The nominations do not say which shingle construction was used, when roofs were replaced or whether a county review was involved. For the wider picture of these neighborhoods, see our guide to the 1940s subdivisions and the slate roofs guide.

On permits, the county's residential page ties a re-roof to how much decking is replaced, not to the covering. The path for houses, townhouses, condos and historic districts is laid out on the Arlington roofing hub, and owners in shared buildings can read how decisions are made in the condo and co-op guide. Confirm your own case with the Permit Arlington Center.

A written scope for a shingle roof

Whoever does the work, these are the items a written scope can state in plain words. Each ties back to a source above.

  • Tear-off or recover, stated plainly, with the number of existing layers and the shingle form (strip or laminated) now on the roof.
  • Deck inspection and what happens to damaged boards or sheets; whether any decking is replaced, with the area, since that decides the county permit question.
  • Underlayment type by its ASTM designation, double where the slope is between 2:12 and 4:12, and the extent of any ice barrier.
  • The shingle's product standard (ASTM D3462), its wind test and class label, and its fire class listing, taken from the package or the manufacturer's literature.
  • Nail type, length and count, and the instruction that the manufacturer's nailing pattern governs.
  • Valley lining type, sidewall and chimney flashing, and drip edge at eaves and rakes.
  • Attic ventilation: the existing intake and exhaust, whether they were checked and whether any change is proposed.
  • Who pulls any permit, and for a condo or co-op who approves the work.

Our roof replacement and roof repair pages cover the wider process, the roofing insurance page covers claims paperwork, and our services list what Roofers of Arlington installs, repairs and replaces. This guide does not say we install any particular shingle product. To talk through your building, book a phone consultation or call (571) 397-6072; we will ask for the address, the building type and what you can see from the ground.

Primary sources and their dates

All pages below were opened on October 25, 2026, except the two county pages, which come from archived copies dated December 2025.

Questions people ask

Is a fiberglass shingle different from an asphalt shingle?

Not as a separate product family. NRCA says asphalt shingles can be reinforced with organic or fiberglass materials, and a fiberglass shingle is the glass-mat version: a fiberglass mat with asphalt on both faces and mineral granules on top. The two names are used for the same kind of roof covering.

What does ASTM D3462 mean on a shingle package?

It is the specification for asphalt shingles made from glass felt and surfaced with mineral granules. NRCA recommends it and says compliance is normally noted in manufacturer literature and on the wrapper. ARMA adds that the standard measures a shingle as manufactured, not after storage or installation.

What do the wind classes D, G, H and A, D, F refer to?

They are classes from two wind tests. ASTM D7158 is an uplift-force method where Class H is the highest; ASTM D3161 is a fan-induced method where Class F is the highest. The Virginia Residential Code asks that the package carry a label showing the test and class that its wind table requires for the site.

Does a fiberglass shingle have a fire rating?

NRCA describes asphalt shingle fire resistance in Classes A, B and C and says fiberglass shingles generally carry Class A, while ARMA notes the test assumes installation to the manufacturer's instructions, including underlayment. Ask for the product's listing rather than assuming.

Can new shingles go over the old layer?

ARMA says local codes may limit the number of coverings and that most manufacturers do not recommend new shingles over existing laminated shingles. It also says tear-off allows the deck to be inspected. Whether a recover is allowed on your building is a question for the county and the shingle manufacturer.

Why does an attic matter for a shingle roof?

ARMA ties attic ventilation to shingle buckling from deck movement, rot, moisture in insulation and ice dams, and says a reroof should include a check of the existing ventilation. That is why the scope below names intake and exhaust vents.

Does Arlington have rules on roofing shingle type?

The county residential permit page we read keys its re-roof table to how much decking is replaced, not to the covering material. In a local historic district, review can apply, and the county says routine repair or replacement with the same materials is excepted. Check your address with the county.

What do the Arlington nominations say about asphalt shingles?

The Arlington Forest nomination records asphalt shingles on all roofs except two standing seam metal roofs. The Glebewood Village nomination records slate shingles replaced with asphalt on some houses and calls those alterations of very little impact on integrity. Neither document names a shingle product.