EPDM roofing in Bethesda, MD: what the Maryland code text names and leaves out

EPDM is a thermoset rubber membrane, and the Maryland building code text names it in a few exact places: a material standard, a minimum slope, a ballast rule and a recover limit. This page reads those lines for Bethesda, in the commercial and residential texts, and marks where the code is silent so that a quote can be checked against it line by line.

  • ASTM D4637 named for EPDM
  • 1/4 in 12 minimum design slope
  • 2 code texts: commercial and residential

What the code names for EPDM

Short version

The Maryland text gives EPDM one standard, one slope, one ballast rule and a set of reroofing limits. It gives no thickness, no seam method and no color. Everything else on an EPDM quote comes from the maker’s instructions and the design professional, and the code sends the reader there.

Chapter 15 of the Maryland Building Code 2021, which adopts the International Building Code, has one section for single-ply roofing, 1507.12. It does not split EPDM into its own heading. EPDM appears as a row in a table, and the rest of the section applies to all single-ply membranes together.

Code lineWhat it says about EPDMWhat it leaves out
Table 1507.12.2EPDM complies with ASTM D4637Membrane thickness and reinforcement
1507.12.1Design slope not less than 1/4 in 12, or 2 percent, for drainageHow to measure it on an existing roof
1507.12.3Under 2 in 12, ballasted roofs follow this section and 1504.5Stone size and weight
1504.5Ballasted low-slope single-ply designed per ANSI/SPRI RP-4The RP-4 content itself
1503.1 and 1507.1Install per the code and the maker’s approved instructionsSeam, adhesive and fastener detail

Maryland Building Code 2021, chapter 15, as published by UpCodes, opened October 20, 2026. UpCodes is a third-party publisher, not the State.

The county’s Master List of Building Codes and Standards shows the 2021 International Building Code and the 2021 International Residential Code, both effective December 10, 2024. The county amendments were not read for this page, so ask DPS whether any change touches a roof covering.

The commercial text and the residential text

Building code, chapter 15

  • Section 1507.12 covers all single-ply membranes at once.
  • EPDM is a table row under ASTM D4637.
  • Ballast, wind testing and edge metal have their own sections.
  • Applies to buildings under the commercial code.

Residential code, chapter 9

  • Section R905.12 is titled thermoset single-ply roofing.
  • Coverings comply with ASTM D4637 or ASTM D5019.
  • Slope is again not less than 1/4 in 12.
  • Installed per the chapter and the maker’s instructions.

The residential text, the MBPS Residential Code 2021 as published by UpCodes, is the one that uses the word thermoset in a heading. It pairs EPDM’s standard with D5019, the standard the commercial table gives to chlorosulfonated polyethylene and polyisobutylene. Thermoplastic membranes such as TPO and PVC sit in the next section, R905.13, with their own standards.

Which text governs depends on the building type, and that is a question for the county or the design professional, not for this page. A townhouse and a high-rise are not read from the same chapter.

Ballast, wind and the test routes

Two routes, by how the membrane is held

For a membrane that is mechanically attached or adhered, sections 1504.4 and 1504.4.1 require resistance to component and cladding pressures and testing under FM 4474, UL 580 or UL 1897. For a ballasted roof under 2 in 12, section 1504.5 sends the design to ANSI/SPRI RP-4 instead, and section 1507.12.3 adds that stone ballast complies with ASTM D448 or ASTM D7655.

The text does not tell a reader how heavy the ballast must be. That number comes from the RP-4 design for the building, which was not opened for this page.

SPRI, the single-ply trade association, notes in an August 2026 post that chapter 15 relies on those three test standards for uplift and that its Directory of Roof Assemblies lists tested low-slope assemblies. It also says to verify code adoption with the authority having jurisdiction.

Recover, tear-off and old parts

The roof-replacement questions on an existing EPDM roof land in section 1512 of the same chapter. Its lines work as a short decision path.

  • First, the coating questionA new protective coating over thermoset or thermoplastic single-ply may be applied without tear-off of existing coverings.
  • Second, a recover over the membraneA new covering over an existing one is permitted where installed under the maker’s approved instructions, and not where the exceptions below apply.
  • Third, the three barsNo recover where the roof is water soaked or deteriorated as a base, where the covering is slate, clay, cement or asbestos-cement tile, or where it already has two or more applications of any covering.
  • Fourth, the parts that stayExisting metal edgings, vent flashing and similar parts “shall not be reinstalled where rusted, damaged or deteriorated.”
  • Fifth, the stone“Existing ballast that is damaged, cracked or broken shall not be reinstalled.”

Section 1512.5 adds that flashings are reconstructed under the maker’s approved instructions. The residential text has a matching recover section with the same coating line for thermoset and thermoplastic single-ply.

On permits, the county’s Residential Restore / Repair page describes a permit to restore or replace part of an existing building to maintain or correct damage, and the Home Improvements page says it does not include municipality or homeowner association rules. The Bethesda roofing guide lays out the permit lanes and the contractor license check.

Drains, scuppers and parapets

1

Overflow

Where roof drains are required and the perimeter rises above the roof so water would be entrapped, secondary drains or scuppers are required. Scupper openings are not less than 4 inches, and ponding depth must stay within the roof design.

2

Flashing

Flashing goes at wall and roof intersections, gutters, changes of slope and roof openings. Metal flashing is not less than 0.019 inch, No. 26 galvanized sheet.

3

Parapets

Parapet walls are coped or covered with weatherproof material at least as wide as the wall thickness, and the top surface provides positive drainage.

Fire class is the other number a flat roof file carries. The code sorts roof coverings into Class A, B and C under ASTM E108 or UL 790, and Table 1505.1 sets a minimum class by construction type. The chapter does not name EPDM in that section, so the class comes from the listing of the whole assembly, not from the membrane word on the quote.

Code lines to check in a Bethesda EPDM quote

  • The slope, measured on site, against the 1/4 in 12 design slope in the text.
  • The membrane standard cited on the product sheet: ASTM D4637 for EPDM.
  • Whether the roof is ballasted, adhered or mechanically attached, since each has its own code route.
  • For ballast, the stone standard (ASTM D448 or D7655) and the RP-4 design the weight comes from.
  • The test or listing relied on: FM 4474, UL 580, UL 1897, or a fire class listing.
  • What happens to old edge metal, flashings, drain outlets and ballast, part by part.
  • The overflow route: scuppers or secondary drains, and where they sit on the parapet.
  • Any written reply from DPS, the owner or the association the scope depends on.

Book a phone consultation to talk through a Bethesda EPDM roof. For the material in general see the EPDM roofing guide, roofing materials, flat roof, roof replacement and services. The Bethesda guide has the local permit and licensing path.

Code and county pages opened for EPDM

Each document below was opened October 20, 2026. UpCodes publishes the Maryland code text; county amendments were not read.

Questions people ask

Which standard does the Maryland code name for EPDM?

ASTM D4637. In the commercial text it sits in the single-ply material table next to ASTM D5019 for CSPE or PIB, D6754 for KEE, D4434 for PVC and D6878 for TPO. The residential text lists thermoset single-ply roof coverings as complying with ASTM D4637 or ASTM D5019. The code names the standard, not a thickness, color or seam method.

What is the minimum slope for an EPDM roof in Bethesda?

Both code texts read the same: a design slope of not less than 1/4 unit vertical in 12 units horizontal, which they state as 2 percent, for drainage. That is a design slope, so it is the slope the roof is designed to have, not a promise that a given building has no low spots. Ask the roofer to measure and write down the slope.

Does the code say how ballasted EPDM must be built?

It points to other documents. For roofs under 2 in 12 the commercial text requires installation under section 1507.12.3 and design under ANSI/SPRI RP-4, and it says stone ballast shall comply with ASTM D448 or ASTM D7655. The text is silent on stone size or weight per square foot here, so that comes from RP-4 and the design professional.

Can a new EPDM roof go over the old roof in Bethesda?

The recover section permits it only in listed conditions and bars it in three: where the existing roof is water soaked or too deteriorated to be a base, where the covering is slate, clay, cement or asbestos-cement tile, and where there are already two or more applications of any covering. A protective coating over an existing single-ply roof may go on without tear-off.

Does the code require a fire class for EPDM?

The commercial text sets a minimum roof covering class by construction type in Table 1505.1, tested to ASTM E108 or UL 790, and it allows nonclassified roofing on some small buildings. It does not name EPDM in that section. Ask the roofer which listed assembly the quote relies on and confirm the construction type with the building owner or the county.

What does Montgomery County list for wind and snow?

The county design criteria sheet dated August 13, 2026 lists a wind speed of 115 mph and a ground snow load of 30 psf. It gives no risk category, does not say whether the speed is ultimate or allowable, and has no value by address. A ground snow load is not a roof design load, so an engineer or DPS confirms the design numbers.

Does the old EPDM edge metal have to be replaced on a re-cover?

The text says existing vent flashing, metal edgings, drain outlets, collars and metal counterflashings shall not be reinstalled where rusted, damaged or deteriorated. It does not order sound edge metal replaced. Ask for the edge condition to be written into the scope, with each reused part named.

Who signs off on an EPDM roof for a condo or apartment building?

The county pages describe building code and permit rules and say they do not cover association rules. Whoever owns the roof under the governing documents signs the scope. To talk through a Bethesda EPDM roof, book a phone consultation, and bring the building type and the association contact.

Talk through your roof with Roofers of Arlington

Share the address, what you are seeing on the roof and the decision you need to make. We will tell you what to expect before anything is scheduled.